300 Kg Steam Boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Clevedon Steam is the UK's number 1 Cheddar Models' spares supplier we stock a range of spares for the Pintail, Pippit, Plover, Puffin and Pelican Steam Engines as well as an expanding range of useful steam boiler fittingsGet Price
Steam Turbine Expansion Path 5.5 6 6.5 7 7.5 8 8.5 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 ENTROPY kJ/kg-K ENTHALPY kJ/kg 160 bar 123.1 bar 153.6 bar 38.61 bar 23 bar 34.3 bar 12.79 bar 7 bar 4.076 bar 1.991 bar 0.873 bar 0.335 bar 0.09 bar Exhaust (LPT0) 0.95 0.9 0.85 0.8 Wilson 0.97 200 C 300 CGet Price
Generally, a steam boiler is a type of closed container, designed with steel for heating the water to generate steam by some energy source like burning of fuel with eventually. The vapor generated may be delivered at low-pressure for the industrial progression work in sugar industries, cotton mills, and for generating steaming water that can be utilized for heat up fixing at much low-force.Get Price
Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566Get Price
MARINE BOILER 2. Dry weight : Boiler body (Excluding water) 3. Working pressure : Accroding to requirement 4. Dimension (W) : Steam drum length 5. For other capacities, please contact us Steam Capacity Working pressure Dry weight (ton/hr) (kg/cm2) LW H (ton) MD01 25 16/22 4,356 3,660 6,620 29.9 MD02 30 16/22 4,724 3,660 7,120 33.5Get Price
The remaining steam continues to expand to 6 kPa. Steam is then condensed at constant pressure and pumped to the boiler pressure of 8 MPa. Steam leaves the process heater as a saturated liquid at 500 kPa. The mass flow rate of steam through the boiler is 20 kg/s.Determine (a) the rate of process heat supply and (b) the net power developed.Get Price
These boilers are used in steam power-driven vehicles as well as mobile machines like railway steam engine, steam tractor, Steam shovels, and steam cranes. 2) Stirling Boiler The Stirling boiler is one type of water tube boiler, used for generating steam (50,000 kg steam/hour and 60 kgf /cm2 pressure) in the large area of the stationary plant.Get Price
The area performance in one working step depends on the capacity of the steam generator (e.g. steam boiler): Steam capacity kg/h: 100 250 300 400 550 800 1000 1350 2000 Area m 2: 15–20 30–50 50–65 60–90 80–120 130–180 180–220 220–270 300–400Get Price
The remaining steam continues to expand to 6 kPa. Steam is then condensed at constant pressure and pumped to the boiler pressure of 8 MPa. Steam leaves the process heater as a saturated liquid at 500 kPa. The mass flow rate of steam through the boiler is 20 kg/s.Determine (a) the rate of process heat supply and (b) the net power developed.Get Price
k. Superheater, drums and boiler tube system maximum design pressure, Vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. l. Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price
These boilers are used in steam power-driven vehicles as well as mobile machines like railway steam engine, steam tractor, Steam shovels, and steam cranes. 2) Stirling Boiler The Stirling boiler is one type of water tube boiler, used for generating steam (50,000 kg steam/hour and 60 kgf /cm2 pressure) in the large area of the stationary plant.Get Price
A boiler explosion is a catastrophic failure of a boiler.There are two types of boiler explosions. One type is a failure of the pressure parts of the steam and water sides. There can be many different causes, such as failure of the safety valve, corrosion of critical parts of the boiler, or low water level. Corrosion along the edges of lap joints was a common cause of early boiler …Get Price
boiler is 420 MW. The working fluid is water/steam, with data at each state provided in the table below; all the pressure values are absolute. State P, bar T, C h, kJ/kg, m3/kg s, kJ/kg-K 1 0.0123 10 42.0 0.00100 0.15109 2 40 10.1 46.3 0.000998 0.15210 3 40 600 3675 0.0988 7.3710 4 0.0123 10 2270 95.7 8.0249Get Price
k. Superheater, drums and boiler tube system maximum design pressure, Vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. l. Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price
The boiler manufacturer should state the maximum total dissolved solids (TDS) in the boiler water at which the required steam purity can be obtained. • The steam as measured at drum outlet should have an impurity not greater than 0.02 mg/kg (ppm mass) silica. The wetness of the steam leaving the drum should not exceed 0.02%. •Get Price
A boiler explosion is a catastrophic failure of a boiler.There are two types of boiler explosions. One type is a failure of the pressure parts of the steam and water sides. There can be many different causes, such as failure of the safety valve, corrosion of critical parts of the boiler, or low water level. Corrosion along the edges of lap joints was a common cause of early boiler …Get Price
300: 400: 485: 520: Steam production (kg steam/kg bagasse) 2.50: 2.36: 2.23: 2.18: Boiler efficiency - LHV basis (%) 85.8: 87.0: 87.2: 87.3: The figures also identify the boiler/turbogenerator unit as the most expensive one in all cases. Figure 2 b) presents the operational cost, identifying the feedstock cost as the highest in all cases Get Price
Aug 21, 2014 · Technological Journey to Supercritical Boiler in India. Steam Parameters for 500 MW units & Super-critical thermal Power plants : 660 MW500 MW Steam Flow- 1625 T/hr SH Presr.- 179 kg/cm2 SH Temp.- 540 0 C RH Temp - 540 o C Steam Flow- 2225 T/hr Steam Flow- 2120 T/hr SH Pres- 255 kg/cm2 SH Temp.- 540 0 C RH Temp - 568 o C SH Presr.- 255 kg/cm2 Get Price
Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566Get Price
Aug 21, 2014 · Technological Journey to Supercritical Boiler in India. Steam Parameters for 500 MW units & Super-critical thermal Power plants : 660 MW500 MW Steam Flow- 1625 T/hr SH Presr.- 179 kg/cm2 SH Temp.- 540 0 C RH Temp - 540 o C Steam Flow- 2225 T/hr Steam Flow- 2120 T/hr SH Pres- 255 kg/cm2 SH Temp.- 540 0 C RH Temp - 568 o C SH Presr.- 255 kg/cm2 Get Price
The main aim is to know boiler, steam turbine and describe cooling towers and condensers. For a thermal power plant the range of pressure may vary from 10 kg/cm2 to super critical pressures and the range of temperature may be from 250°C to 650°C. BTPP produces 300 metric ton coal combustion FA per day by burning 2,400 metric ton of Get Price
Steam Turbine Expansion Path 5.5 6 6.5 7 7.5 8 8.5 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 ENTROPY kJ/kg-K ENTHALPY kJ/kg 160 bar 123.1 bar 153.6 bar 38.61 bar 23 bar 34.3 bar 12.79 bar 7 bar 4.076 bar 1.991 bar 0.873 bar 0.335 bar 0.09 bar Exhaust (LPT0) 0.95 0.9 0.85 0.8 Wilson 0.97 200 C 300 CGet Price
boiler is 420 MW. The working fluid is water/steam, with data at each state provided in the table below; all the pressure values are absolute. State P, bar T, C h, kJ/kg, m3/kg s, kJ/kg-K 1 0.0123 10 42.0 0.00100 0.15109 2 40 10.1 46.3 0.000998 0.15210 3 40 600 3675 0.0988 7.3710 4 0.0123 10 2270 95.7 8.0249Get Price
The area performance in one working step depends on the capacity of the steam generator (e.g. steam boiler): Steam capacity kg/h: 100 250 300 400 550 800 1000 1350 2000 Area m 2: 15–20 30–50 50–65 60–90 80–120 130–180 180–220 220–270 300–400Get Price
Generally, a steam boiler is a type of closed container, designed with steel for heating the water to generate steam by some energy source like burning of fuel with eventually. The vapor generated may be delivered at low-pressure for the industrial progression work in sugar industries, cotton mills, and for generating steaming water that can be utilized for heat up fixing at much low-force.Get Price
The boiler manufacturer should state the maximum total dissolved solids (TDS) in the boiler water at which the required steam purity can be obtained. • The steam as measured at drum outlet should have an impurity not greater than 0.02 mg/kg (ppm mass) silica. The wetness of the steam leaving the drum should not exceed 0.02%. •Get Price
Largest mean overload = 10 300 kg/h for 30 minutes every 95 minutes. Pressure = 5 bar g. Required steam storage = 10 300 kg/h - 5 000 kg/h steam supplied by the boiler. Required steam storage = 5 300 kg/h. However, steam is only required for 30 minutes every hour, so the steam storage required must beGet Price
Jan 27, 2010 · If you are happy about fuel and water supplies and with an electrical power demand ranging from 2 to 6 kw your cut wood requirements will range between 120 kg to 360 kg per hour with steam requirements ranging from 40 to 120 kg per hour. A 10 HP ( 7.5 kw ) steam engine coupled with a boiler capable of 150 kg per hour would cover fluctuating Get Price
Steam Solutions The PARAT Electrode Boiler is the world leading solution for High Voltage Electrode Steam Boilers. With steam pressure range of 6 - 85 barg and capacity up to 60 MW, you have the solutions for small and large capacity steam production. This is the perfect boiler to replace your fossil fuel steam boilers with clean electrical heat.Get Price
Largest mean overload = 10 300 kg/h for 30 minutes every 95 minutes. Pressure = 5 bar g. Required steam storage = 10 300 kg/h - 5 000 kg/h steam supplied by the boiler. Required steam storage = 5 300 kg/h. However, steam is only required for 30 minutes every hour, so the steam storage required must beGet Price